PRODUCT NAME: Precision Polyurethane HMIS CODES: H F R P
PRODUCT CODE: PF-435 Matte, PF-450 Semi-Gloss, PF-490 Gloss 2 2 1 K
SECTION I - MANUFACTURER IDENTIFICATION
MANUFACTURER'S NAME: Precision Technology LLC
ADDRESS: 4052 Getwell Road
Memphis, TN 38118
EMERGENCY PHONE: 877-363-0088 DATE PRINTED: November 15, 2003
INFORMATION PHONE: 901-363-0526 NAME OF PREPARER: Precision Technology LLC
SECTION II - HAZARDOUS INGREDIENTS / SARA III INFORMATION
OCCUPATIONAL EXPOSURE VAPOR PRESSURE
__________________________________________________________________________________________
*Aliphatic Hydrocarbon 8052-41-3 100 PPM 100 PPM 2.0 68oF 46
*Aliphatic Hydrocarbon 64742-89-8 300 PPM 300 PPM 10.2 68oF 2
*Xylene 1330-20-7 100 PPM 100 PPM 2.4 68oF 2
* Indicates toxic chemical(s) subject to the reporting requirements of Section 313 of Title III and of 40 CFR 372.
SECTION III - PHYSICAL / CHEMICAL CHARACTERISTICS
BOILING RANGE: 246oF to 318oF SPECIFIC GRAVITY (H2O=1): 0.9
VAPOR DENSITY: Heavier Than Air EVAPORATION RATE: Slower than Ether
COATING V.O.C.: MAX 4.23 lb/gL (507 g/L) MATERIAL V.O.C.: 4.23 lb/gL (507 g/L)
SOLUBILITY IN WATER: Neglibible
APPEARANCE AND ODOR: Med visc liquid / Solvent odor
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
FLASH POINT: 105oF METHOD USED: TCC
FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: 0.7% UPPER: 8.0%
EXTINGUISHING MEDIA: Water, alcohol foam, CO2, dry chemicals, water fog
SPECIAL FIREFIGHTING PROCEDURES:
Firefighters and others exposed to vapors or products of combustion should wear self-contained breathing apparatus.
UNUSUAL FIRE AND EXPLOSION HAZARDS
Vapors may form an explosive mixture in air, closed containers may rupture when exposed to extreme heat, air oxidation of this product may cause it to spontaneously combust. To avoid spontaneous combustion, soak soiled rags, spray both filters and filters and oversprayed material in a water filled metal container.
SECTION V – REACTIVITY DATA
STABILITY: Stable
CONDITIONS TO AVOID:
Avoid heat and open flames, poor ventilation, corrosives.
INCOMPATIBILITY (MATERIALS TO AVOID):
Avoid strong oxidizing agents.
HAZARDOUS DECOMPOSITION OR BYPRODUCTS
CO, CO2 and unidentified organics may form from combustion.
HAZARDOUS POLYMERIZATION
Will not occur
SECTION VI – HEALTH HAZARD DATA
INHALATION HEALTH RISKS AND SYMPTOMS OF EXPOSURE
High vapor concentration (greater than 1000 PPM) are irritating to eyes, respiratory tract, causing headache, dizziness and other central nervous system effects.
SKIN AND EYE CONTACT HEALTH RISKS AND SYMPTOMS OF EXPOSURE
Eye Contact: Severe irritation, redness and blurred vision.
Skin Contact: Redness, burning and irritation
SKIN ABSORPTION HEALTH RISKS AND SYMPTOMS OF EXPOSURE
Irritation and dermatitis.
INGESTION HEALTH RISKS AND SYMPTOMS OF EXPOSURE
Gastrointestinal irritation, vomiting and nausea.
HEALTH HAZARDS (ACUTE AND CHRONIC)
Acute: See above
Chronic: Overexposure to solvents may cause permanent central nervous system damage.
CARCINOGENICITY
NTP CARCINOGEN: No IARC MONOGRAPHS: No OSHA REGULATED: Yes
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE
Anesthesia, respiratory tract irritation, dermatitis, vomiting.
This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.
EMERGENCY AND FIRST AID
Inhalation: Remove to fresh air, call physician, begin resuscitation if breathing irregular.
Eye contact: Flush with large quantities of water for at least 15 minutes. Get medical attention.
Skin contact: Flush with water, follow by soap and water wash. Remove contaminated clothing.
Ingestion: DO NOT induce vomiting. Dilute with milk or water. Get medical attention immediately.
SECTION VII – PRECAUTIONS FOR SAFE HANDLING AND USE
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
See reactivity conditions to avoid. Empty containers contain residue and can be dangerous. DO NOT weld, solder, braze, grind or expose to ignition sources.
OTHER PRECAUTIONS
If spilled or leaked, shut off and eliminate all ignition sources, spread suitable absorbent and remove in accordance with local, state, and federal regulations for hazardous waste.
SECTION VIII – CONTROL MEASURES
RESPIRATORY PROTECTION
Use NIOSH approved respirator for organic vapors according to 29 CFR 1910.134. For confined areas of minimal ventilation use self contained breathing apparatus.
VENTILATION
Explosion proof, no smoking.
PROTECTIVE GLOVES
Impervious to solvents. Neoprene suggested.
EYE PROTECTION
Chemical splash goggles recommended.
OTHER PROTECTIVE CLOTHING OR EQUIPMENT
Chemical resistant apron or other impervious clothing.
WORK / HYGIENIC PRACTICES
Minimize breathing vapor or mist. Avoid skin and clothing contact. Wear appropriate clothing to protect skin.
SECTION IX – SPILLAGE OR LEAK PROCEDURE
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Small spills: Absorb liquid on paper vermiculite, floor absorbent or other media and transfer to hood.
WASTE DISPOSAL METHOD
Containers must be leak-proof and tightly sealed. Dispose in accordance with local, state, and federal regulations for hazardous waste.
SECTION X – DISCLAIMER
Data relates only to the specific product described and not to such product in combinations with any other product and no agent for Precision Technology LLC is authorized to vary any such data. Precision Technology LLC and its agents disclaim all liability for any actions taken of forgone reliance upon such data.